Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation
Published on: October 10, 2018
Dielectric spectroscopy and electrophoretic mobility measurements interpreted with the standard electrokinetic model
A D Hollingsworth1, D A Saville
1Department of Chemical Engineering, Princeton University, Princeton, NJ 08544, USA.
Abstract:
We report results from complementary electrokinetic measurements-dielectric relaxation and electrophoretic mobility-undertaken to test the applicability of the standard electrokinetic theory with a model system. Dielectric spectra were obtained at frequencies between 1 kHz and 40 MHz with a new, two-electrode cell design [Hollingsworth and Saville, J. Colloid Interface Sci. 257 (2003) 65-76]; mobility data were acquired with an electrophoretic light scattering instrument. Data from the two-electrode cell were collected at different electrode separations and interpreted with newly developed procedures to remove the influence of electrode polarization. Methodology A employs extrapolation to infinite electrode separation to compute the dielectric constant and conductivity as functions of frequency. The contributions from suspended particles are reported in terms of dielectric constant and conductivity increments. Methodology B uses a theoretical model of electrode polarization and the standard electrokinetic model in a nonlinear regression scheme. Results are presented in several forms: frequency-dependent dielectric constant and conductivity increments, frequency-dependent dielectric constants and conductivities, and the complex dipole coefficient. It is shown that the standard model provides a consistent methodology for interpreting particle behavior; zeta-potentials inferred from mobility and dielectric relaxation agree to within experimental error. Moreover, the cell design and interpretation are straightforward and provide relatively simple ways to obtain complementary measurements over a wide frequency range. The results unambiguously show that electrokinetic character of this dispersion follows the standard model.
More Related Videos
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrochemical Systems
The Electrical Double Layer