Related Experiment Video
Updated: Aug 26, 2026

Heterotopic and Orthotopic Tracheal Transplantation in Mice used as Models to Study the Development of Obliterative Airway Disease
Published on: January 20, 2010
Experimental study of a new tracheal prosthesis: pored Dacron tube
Hisashi Tsukada1, Hiroaki Osada
1Department of Surgery, Division of Chest Surgery, St. Marianna University School of Medicine, 2-16-1 Sugao Miyamae-ku, Kawasaki, Japan. h2tukada@marianna-u.ac.jp
Objective:
This study was designed to evaluate how various sizes and densities of pores in Dacron tubing might enhance its utility as a tracheal prosthesis.
Methods:
A vascular prosthesis made of knitted external velour polyester was prepared for pore formation with a laser. The first set compared different pore sizes (300, 500, and 700 microm) and pore densities (25/cm(2) or 100/cm(2)). Grafts were reinforced with an externally heat-sealed silicone ring. The second set tested grafts with a pore density of 64/cm(2) and a pore size of 500 microm internally reinforced with a stainless-steel spiral stent. In all experiments, a canine mediastinal trachea 10 cartilage rings in length was resected, and the prosthesis was then implanted with an omental flap.
Results:
Lower pore size and density (300 microm, 25 pores/cm(2)) led to essentially no tissue ingrowth. Larger pore size (700 microm) and low density (25 pores/cm(2)) led to rapid and excessive ingrowth of granulation. Midrange pore size (500 microm) and high density (100 pores/cm(2)) invited steady tissue ingrowth, but marked luminal stenosis eventually developed. Stent-reinforced prostheses with 500-microm pores at 64 pores/cm(2), as used in the second set, maintained an average patency rate of 60% or more (range, 20%-100%) at least 12 months after implantation.
Conclusion:
Our data show that porosity is a key factor for tissue growth through our Dacron tracheal prostheses. This artificial trachea model has led to long-term survivors up to 27 months after the operation and seems promising as a basic model for clinical tracheal repair.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

