Related Experiment Video
Updated: Aug 25, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
The relationship between single-breath diffusion capacity of the lung for nitric oxide and carbon monoxide during
Gerald S Zavorsky1, Karine Badra Quiron, Philip S Massarelli
1Department of Exercise Science, Concordia University, Montreal, QC, Canada. zavorsky@alcor.concordia.ca
Study Objectives:
To determine the relationship between single-breath diffusion capacity of the lung for nitric oxide (DLNO) and single-breath diffusion capacity of the lung for carbon monoxide (DLCO), and to determine the single-breath DLNO/DLCO ratios during rest and at several exercise intensities using a commercial lung diffusion system that uses electrochemical cells to analyze gases.
Setting And Participants:
Eight healthy men (age, 27 +/- 5 years; weight, 83.0 +/- 11.8 kg; height, 180.4 +/- 9.5 cm; maximal oxygen uptake [VO(2)max], 47.6 +/- 10.2 mL/kg/min [mean +/- SD]) performed single-breath DLNO measurements (inspired nitric oxide concentration, 66.5 +/- 10.6 ppm) and carbon monoxide (0.30%) randomized on different days at rest and at various exercise intensities (40%, 75%, and 90% of VO(2)max reserve [VO(2)R]) on a electrically braked load simulator. The DLCO measured on day 1 was compared to the DLCO measured during the DLNO method from another day.
Results:
The relationship between DLNO and DLCO was linear (DLNO = 4.47 x DLCO; r(2) = 0.91; standard error of the estimate = 0.04; p < 0.05). DLNO was 4.52 +/- 0.24 times greater than DLCO, independent of exercise intensity. DLNO increased from 210.3 +/- 18.2 mL/min/mm Hg at rest to 284.2 +/- 38.6 mL/min/mm Hg at 90% VO(2)R (oxygen uptake = 42.6 +/- 9.8 mL/kg/min; 284.2 +/- 31.6 W; p < 0.05). Stepwise regression demonstrated that DLNO is predicted by alveolar volume (VA) [in liters] and workload (watts) such that DLNO = 13.4 x VA + 0.23 x workload + 107.7 (r(2) = 0.90; SEE = 17.5; p < 0.05).
Conclusion:
(1) Single-breath DLNO and DLCO increase linearly with increasing workload; (2) the single-breath DLNO/DLCO ratios are independent of exercise intensity, suggesting that using either nitric oxide or carbon monoxide as transfer gases are valid in the study of lung diffusion during any level of exercise; and (3) DLNO is mainly predicted by VA and workload.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Gas Exchange and Transport
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
External and Internal Respiration
Lung Capacity
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves the...