Related Experiment Video
Updated: Aug 25, 2026

The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
Axillary staging using positron emission tomography in breast cancer patients qualifying for sentinel lymph node
Mathias K Fehr1, Rene Hornung, Zsuzsanna Varga
1Department of Obstetrics and Gynecology, University Hospital, Zurich, Switzerland. Mathias.Fehr@fhk.usz.ch
Abstract:
Axillary lymph node dissection (ALND) is the standard of care for nodal staging of patients with invasive breast cancer. Due to significant somatic and psychological side effects, replacement of ALND with less invasive techniques is desirable. The goal of this study was to evaluate the clinical usefulness of axillary lymph node (ALN) staging by means of positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG) in breast cancer patients qualifying for sentinel lymph node biopsy (SLNB). FDG-PET was performed within 1 week before surgery in 24 clinically node-negative breast cancer patients with tumors smaller than 3 cm. Sentinel lymph nodes (SLNs) were identified by preoperative lymphoscintigraphy following peritumoral technetium 99m-labeled colloid albumin injection, and by intraoperative gamma detector and blue dye localization. Following SLNB, a standard ALND was performed. Serial sectioning and immunohistochemistry of the SLN as well as standard histologic examination of the non-SLN was performed. FDG-PET detected all primary breast cancers. Staging of ALNs by PET was accurate in 15 of 24 patients (62.5%), whereas PET staging was false negative in 8 of 10 node-positive patients and false-positive in 1 patient. The sensitivity, specificity, positive predictive value, and negative predictive value of FDG-PET for nodal status was 20%, 93%, 67%, and 62%, respectively. The mean diameter of false-negative ALN metastases was 7.5 mm (range 1-15 mm). Lymph node staging using FDG-PET is not accurate enough in clinically node-negative patients with breast cancer qualifying for SLNB and should not be used for this purpose.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
