Laser Doppler skin perfusion pressure in the assessment of Raynaud's phenomenon
T Kanetaka1, T Komiyama, A Onozuka
1Division of Vascular Surgery, Department of Surgery, University of Tokyo, Tokyo, Japan.
Objectives:
In the assessment of Raynaud's phenomenon, objective evaluation of digital microcirculatory flow is important, and so we investigated whether the measurement of laser Doppler skin perfusion pressure could be of use.
Materials And Methods:
Ten fingers of five patients with secondary Raynaud's phenomenon due to systemic sclerosis, 22 fingers of 11 patients with primary Raynaud's phenomenon and 10 fingers of five control patients were examined. Skin perfusion pressure was measured on the third finger of both hands at rest, and then again 3 min after local cold exposure.
Results:
Laser Doppler skin perfusion pressure at rest in patients with secondary Raynaud's phenomenon was significantly lower than that in patients with primary Raynaud's phenomenon and the control patients (p<0.05). Skin perfusion pressure decreased significantly in both patient groups upon local cold exposure (p=0.005). There were significant differences in perfusion pressure after cold exposure among both groups (p<0.05).
Conclusions:
The low skin perfusion pressure at rest in patients with secondary Raynaud's phenomenon suggested the presence of obstructive arterial lesions. The marked pressure decrease in all Raynaud's patients after local cold exposure might be due to vasospasm of the microvasculature in the digits. These results indicate that the measurement of laser Doppler skin perfusion pressure is valuable in the diagnosis of Raynaud's phenomenon.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse
The pulse serves as a clinical indicator...