Related Experiment Video
Updated: Aug 25, 2026

Mass Spectrometric Analysis of Glycosphingolipid Antigens
Published on: April 16, 2013
Analysis of glycerophosphoinositol by liquid chromatography-electrospray ionisation tandem mass spectrometry using a
Luana K Dragani1, Christopher P Berrie, Daniela Corda
1G. Paone Environmental Health Center, Mario Negri Institute for Pharmacological Research, Consorzio Mario Negri Sud, Via Nazionale, Santa Maria Imbaro, 66030 Chieti, Italy. dragani@negrisud.it
Abstract:
Glycerophosphoinositol (GroPIns) has been demonstrated to have important roles in many intracellular regulatory processes. GroPIns has been analysed for many years by anion-exchange HPLC after radiolabelling of cells in culture, but no method has been developed, to our knowledge, for the direct detection and quantitation of the unlabelled compound in such biological samples. Here is reported a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the direct quantitative analysis of GroPIns that can indeed be applied to cell extracts. Analyses were performed on a beta-cyclodextrin-bonded HPLC column using a binary mobile phase of acetonitrile and 20 mM ammonium formate in water, which allowed direct on-line detection by tandem mass spectrometry in negative electrospray ionisation (ESI) mode. The method was applied to the quantitative analysis of GroPIns in selected rat cell lines after a two-phase acid extraction of cultured cells using external calibration. The potential matrix signal suppression effects were investigated by the parallel quantitation of GroPIns in extracts of selected cultured cell lines with both external calibration and the standard additions method. The accuracy data obtained demonstrated the feasibility of external calibration, so allowing a simpler and less time-consuming approach than that of the standard additions method.
More Related Videos
09:22Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
Published on: August 13, 2021
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
Related Concept Videos
Ion-Exchange Chromatography
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...