Related Experiment Video
Updated: Aug 25, 2026

Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
Acute effects of continuous and intermittent vibration on finger circulation
Massimo Bovenzi1, Alexandra J L Welsh, Michael J Griffin
1Department of Public Health Sciences, Trieste General Hospitals, University of Trieste, Via della Pietà 19, 34129, Trieste, Italy. bovenzi@units.it
Objectives:
To compare the acute response of finger circulation to continuous and intermittent vibration having the same total duration of vibration exposure and the same energy-equivalent acceleration magnitude.
Methods:
Finger blood flow (FBF) was measured in the middle and little fingers of both hands of ten healthy men. Finger skin temperature (FST) was measured in the middle right finger. With a static load of 10 N, the middle finger of the right hand was exposed to 125 Hz at 44 m s(-2) root mean square (r.m.s.) in five conditions: (1). 30 min continuous exposure, (2). two periods of 15 min, separated by a 15 min period with no vibration, (3). four periods of 7.5 min, separated by 7.5 min periods with no vibration, (4). eight periods of 3.75 min, separated by 3.75 min periods with no vibration, (5). 16 periods of 1.88 min, separated by 1.88 min periods with no vibration. All five exposures correspond to an 8 h energy-equivalent frequency-weighted acceleration magnitude of 1.4 m s(-2) r.m.s. according to International Standard ISO 5349-1 (2001). Finger circulation was measured in all four digits before the application of vibration and at fixed intervals during vibration exposure and during a 45 min recovery period.
Results:
The FST did not change during vibration exposure, whereas all vibration conditions produced significant reductions in FBF of the vibrated finger when compared with the pre-exposure FBF. During vibration exposure, the vibration caused a similar degree of vasoconstriction in the vibrated finger without evidence of cumulative effects during intermittent exposure. After the end of exposure to 30 min of continuous vibration there was a progressive decrease in the FBF, whereas there was no statistically significant reduction following exposure to intermittent vibration.
Conclusions:
For the vibration stimuli investigated (exposure durations varying from 1.88 min to 30 min, with rest periods varying from 1.88 min to 15 min), the reduction of FBF during exposure was the same for continuous and intermittent vibration. The after effect of vibration was greater following the continuous vibration exposure. Although some evidence from this study is consistent with the notion that intermittent vibration has a less severe effect than continuous vibration, this evidence is not yet conclusive.
Related Concept Videos
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Vascular Spasm
Pulse
The pulse serves as a clinical indicator...
