Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
Li-xin Chen1, Xin-fang Wang, Navin C Nanda
1Department of Echocardiography, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China.
Background:
Both real-time three-dimensional echocardiography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects.
Methods:
Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n = 6) or distal branch of the left circumflex artery (LCX, n = 7) under general anaesthesia. Three to four ml of a perfluoropropane (C3F8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and right coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals' hearts were used as controls.
Results:
Left ventricular (LV) mass determined by RT3DE ranged 36.7 - 68.9 g [mean, (54.6 +/- 9.6) g] before coronary artery ligation, and correlated highly (r = 0.99) with in vitro measurement of LV mass [range, 38.9 - 71.1 g; mean, (55.6 +/- 9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7 - 68.9 g; mean, (51.3 +/- 12.5) g. Or range, 38.9 - 71.1 g; mean, (53.7 +/- 12.3) g, respectively] and under-perfused mass [range, 0 - 21.4 g; mean, (12.0 +/- 6.9) g. Or range, 0 - 19.8 g; mean, (10.8 +/- 6.3) g, respectively] after the LAD ligation (P > 0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1 - 65.4 g; mean, (57.5 +/- 5.9) g. Or range, 51.5 - 65.8 g; mean, (57.3 +/- 6.4) g, respectively] and under-perfused mass [range, 0 - 25.6 g; mean, (13.3 +/- 9.6) g. Or range, 0 - 22.7 g; mean, (12.8 +/- 8.1) g, respectively] after the LCX ligation (P > 0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9 - 68.6 g [mean, (54.8 +/- 10.0) g] and there was no significant difference between RT3DE and in vitro measurements of LV mass and under-perfused mass (P > 0.05, r = 0.99). Further, the under-perfused mass derived from RT3DE [range, 0 - 25.6 g; mean, (12.7 +/- 8.2) g] correlated strongly with the in vitro measurements [range, 0 - 22.7 g; mean, (11.9 +/- 7.2) g] (r = 0.96).
Conclusion:
RT3DE with MCE is a rapid and accurate method for estimating LV myocardial mass and quantifying perfusion defects.
More Related Videos
06:533D Whole-heart Myocardial Tissue Analysis
Published on: April 12, 2017
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...