Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with
Andreea I Nica1,2, Christian Booz1,2, Giuseppe M Bucolo3
1Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt Am Main, Germany.
Abstract:
Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retrospectively evaluated 125 patients who underwent dual-source photon-counting CTA scans of thoracic arteries. We reconstructed standard CT images at 120 kV and VMI series at 15 keV intervals, ranging from 40 to 100 keV, and conducted quantitative and qualitative image analyses. For quantitative analysis, we assessed vascular CT numbers and contrast-to-noise ratio (CNR). For qualitative evaluation, three board-certified radiologists independently rated image quality, vascular contrast, and diagnostic assessability of the thoracic arteries using a five-point scale. Results: Quantitative image analysis revealed that 40 keV VMI reconstructions exhibited the highest mean CT value (HU: 1205 ± 286) and CNR (29.22 ± 9.13), followed by the 55 keV series (HU: 679 ± 161, CNR: 22.54 ± 7.36), significantly improved compared to higher keV levels and the standard 120 kV CT series (p < 0.001). Qualitative analysis showed the highest rating scores for 55 keV reconstructions, significantly higher than those of VMI series at higher energy levels and the standard 120 kV series (p < 0.001). Conclusions: VMI reconstructions at low energy levels (40-55 keV) significantly enhance vascular CTvalue and CNR, offering superior image quality and diagnostic assessability for thoracic arteries compared to standard CT series in photon-counting CTA.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT