Plaque-Adapted Virtual Monoenergetic Image Selection for Carotid Plaque Visualization Using Photon-Counting CT
Mirela Kostadinova1, Lea B Uebelacker1, Tommaso D'Angelo2
1Clinic for Radiology and Nuclear Medicine, University Hospital Frankfurt, Goethe University, 60590 Frankfurt am Main, Germany.
Abstract:
Objectives: The objective of this study was to evaluate the impact of virtual monoenergetic image (VMI) reconstructions derived from photon-counting computed tomography (PCCT) on the assessment of carotid arteries, with a focus on optimizing keV selection based on plaque composition. Methods: This retrospective study included 111 patients (mean age 80 ± 7.5 years; 64 men; 47 women) with carotid sclerosis who underwent PCCT between April 2022 and February 2023. One lesion was analyzed per patient, each containing both calcified and non-calcified components. Quantitative measurements were performed in calcified plaque across energy levels from 40 to 120 keV and comprised attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), corrected image noise (CIN) and artifact index (AIX). Two radiologists independently rated image quality, artifacts, and diagnostic assessability of both components using five-point scales. Results: Attenuation and CNR were highest at 40 to 50 keV, where CIN and AIX were also greatest. SNR followed a U-shaped course, lowest at 90 keV and highest at 110 to 120 keV, where intraluminal attenuation was too low for reliable luminal delineation. Reader ratings were highest at 40 to 50 keV for non-calcified components and at 70 to 80 keV for calcified plaque, with good interobserver agreement throughout (κ 0.74 to 0.92). After correction for multiple testing, adjacent energy levels were frequently indistinguishable. Conclusions: Optimal PCCT VMI energy levels depend on plaque composition. The findings support implementing standardized protocols with automatic dual-range reconstructions (40-50 keV and 70-80 keV) to enable efficient, individualized carotid plaque assessment in clinical practice.
More Related Videos
08:13Microwave-driven Synthesis of Iron Oxide Nanoparticles for Fast Detection of Atherosclerosis
Published on: March 22, 2016
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT