[Correction of high myopia with anterior chamber angle-supported phakic intraocular lenses--own results]
Stanisława Gierek-Ciaciura1, Krzysztof Ochalik, Ariadna Gierek-Łapińska
1Samodzielnego Publicznego Szpitala Klinicznego nr 5 Slaskiej Akademii Medycznej w Katowicach.
Purpose:
To evaluate the early results: predictability, efficacy and safety of implanting new model of anterior chamber IOL for high myopia.
Material And Methods:
ICARE myopia lens (Corneal) was implanted in 20 eyes of 12 patients with preoperative myopia that ranged from -10 D to 23.5 D. Mean patient age was 32.3 years. The follow-up period was 6 months. The desired outcome was emmetropia.
Results:
Eighteen eyes (85%) had a postoperative refraction at the last follow-up examination in a range +/- 1.0 D of emmetropia. The postoperative refraction remained stable during the entire follow-up period. Mean visual acuity before surgery, corrected with spectacle improved from 0.5 to 0.68 postoperatively without glasses in 3 months time. There was no loss in visual acuity after operation. We didn't encounter major complications. Mean endothelial cell density reduction was 3.2% in our 3 months study.
Conclusions:
Implantation of ICARE myopia lens to correct high myopia resulted in a stable and predictable refractive outcome. Further investigation is necessary to evaluate long-term stability and safety of this procedure.