Related Experiment Video
Updated: Aug 25, 2026

Microdialysis of Ethanol During Operant Ethanol Self-administration and Ethanol Determination by Gas Chromatography
Published on: September 5, 2012
Development and application of an integrated system for monitoring ethanol content of fuels
Eliana M Alhadeff1, Andrea M Salgado, Nei Pereira
1Departamento de Engenharia Química, Escola de Química, CT/UFRJ, Ilha do Fundão, Cidade Universitária, CEP 21.949.900, Rio de Janeiro, RJ, Brasil.
Abstract:
An automated flow injection analysis (FIA) system for quantifying ethanol was developed using alcohol oxidase, horseradish peroxidase, 4-amino-phenazone, and phenol. A colorimetric detection method was developed using two different methods of analysis, with free and immobilized enzymes. The system with free enzymes permitted analysis of standard ethanol solution in a range of 0.05-1.0 g of ethanol/L without external dilution, a sampling frequency of 15 analyses/h, and relative SD of 3.5%. A new system was designed consisting of a microreactor with a 0.91-mL internal volume filled with alcohol oxidase immobilized on glass beads and an addition of free peroxidase, adapted in an FIA line, for continued reuse. This integrated biosensor-FIA system is being used for quality control of biofuels, gasohol, and hydrated ethanol. The FIA system integrated with the microreactor showed a calibration curve in the range of 0.05-1.5 g of ethanol/L, and good results were obtained compared with the ethanol content measured by high-performance liquid chromatography and gas chromatography standard methods.
Related Concept Videos
Production of Alcohol
Bioreactor Controls-I
Biofuels
Bioreactor Design and Operational System