[3-D navigation in the petrous bone with submillimeter accuracy].

F Kral1, W Freysinger

  • 1Klinische Abteilung für allgemeine Hals-, Nasen- und Ohrenerkrankungen der Universitätsklinik für Hals-, Nasen- und Ohrenheilkunde.

HNO
|April 7, 2004
PubMed
Summary

Computer-aided navigation in the petrous bone achieves submillimeter accuracy using high-resolution CT imaging and specialized referencing. This technology is suitable for sensitive surgical applications in the petrous bone and cerebellopontine angle.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pre-surgery planning tool for estimation of resection volume to improve nasal breathing based on lattice Boltzmann fluid flow simulations.

International journal of computer assisted radiology and surgery·2021
Same author

Nasal cavity airflow: Comparing laser doppler anemometry and computational fluid dynamic simulations.

Respiratory physiology & neurobiology·2020
Same author

Custom implant design for large cranial defects.

International journal of computer assisted radiology and surgery·2016
Same author

Intractable Posterior Epistaxis due to a Spontaneous Low-Flow Carotid-Cavernous Sinus Fistula: A Case Report and a Review of the Literature.

Case reports in otolaryngology·2016
Same author

[Intralesional Embolization of a Highly Vascularized Paranasal Sinus Tumor].

Laryngo- rhino- otologie·2015
Same author

No association between obesity and post-tonsillectomy haemorrhage.

The Journal of laryngology and otology·2014

Area of Science:

  • Neurosurgery
  • Medical Imaging
  • Computer-Aided Surgery

Background:

  • Evaluating submillimeter accuracy for computer-aided navigation in the petrous bone.
  • Utilized a Zeiss STN intraoperative navigation system for approximately 3,000 measurements on an anatomic specimen.
  • Enabled direct measurement of normally inaccessible petrous bone structures.

Purpose of the Study:

  • To assess the accuracy of intraoperative 3-D navigation in the petrous bone.
  • To determine optimal imaging and referencing techniques for precise surgical guidance.

Main Methods:

  • Employed multislice CT imaging with 0.5 mm slice thickness and direct radiologic imaging.
  • Utilized an extrinsic marker structure (VBH-referencing element) for patient-to-image referencing.

Related Experiment Videos

  • Compared results with and without additional surface registration from the navigation system.
  • Main Results:

    • Best accuracy achieved with high-resolution CT (0.5 mm slice spacing), direct imaging, and extrinsic referencing.
    • An absolute positioning difference of 0.42+/-0.69 mm was observed in optimal conditions.
    • Additional surface registration did not improve the achieved accuracy.

    Conclusions:

    • Intraoperative 3-D navigation demonstrates satisfactory accuracy for clinical application in the petrous bone and cerebellopontine angle.
    • The technology is viable even with restricted patient areas for referencing.