Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 10, 2014
Thermal and temporal response of ionization chambers in radiation dosimetry
1Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA. das@xrt.upenn.edu
Abstract:
The temporal and thermal response of various commonly used ion chambers (NEL, Exradin, PTW) with different wall and electrode materials is studied in a water phantom. Measurements were taken in heating water bath having an automatic temperature control mechanism. All chambers were submersed at 3 cm depth in water phantom and connected to separate electrometers for simultaneous readings for a given dose from a 6 MV beam. The temporal response was studied at approximately +/- 10 degrees C from room temperature, i.e., 10 degrees C and 30 degrees C. Temporal results show that all chambers reach quick equilibrium response within < 2 minutes of submersion in water. The steady-state thermal response was dependent upon the water temperature and wall and electrode compositions. The temperature and pressure corrected response of the NEL chamber was least affected by the changes in water temperature, where as the Exradin chamber has positive and PTW has negative slope with water temperature. The response varied within +/-1.5% between 10 degrees C-50 degrees C temperature and is mainly dependent on volume changes rather than the humidity. A correction factor based on thermal coefficients is derived for each chamber. It is concluded that ion chamber correction factors can be divided into first order; temperature and pressure connection, second order; volume correction for thermal expansion, and third order; humidity correction. To eliminate dosimetric error, the temporal and thermal response should be known for a chamber or water phantom temperature should be maintained close to room temperature.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Absorption of Radiation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Determination of Crystal Structures