Related Experiment Videos
Shear strength of laboratory-processed composite resins bonded to a silane-coated nickel-chromium-beryllium alloy
H Kolodney1, A D Puckett, K Brown
1Department of Restorative Dentistry, University of Mississippi, School of Dentistry, Jackson.
Abstract:
The shear bond strengths of three commercial laboratory curing composite resin veneers bonded to a nickel-chromium-beryllium alloy treated with the Silicoater system were evaluated. Two light-cured resins and one heat- and pressure-cured resin were evaluated. No statistically significant difference in bond strengths among the three resins was found. Microscopic analysis of the fracture surfaces indicated that all failures were complex and cohesive in nature within the resin and composite. On the basis of the shear bond strengths measured, any of the composite resin veneers tested appear to be clinically acceptable.