Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
Effect of radiant warmer on transepidermal water loss (TEWL) and skin hydration in preterm infants
A Maayan-Metzger1, G Yosipovitch, E Hadad
1Department of Neonatology, Schneider Children's Medical Center of Israel, 14 Kaplan Street, Petah Tikva 49-202, Israel.
Insights
Radiant warmers did not significantly impair preterm infants' skin barrier function. While transepidermal water loss (TEWL) increased slightly on the forehead and back, overall skin hydration remained unaffected, indicating safe use.
Area of Science:
- Neonatal care
- Dermatology
- Pediatrics
Background:
- Preterm infants have immature skin barriers, making them vulnerable to environmental factors.
- Radiant warmers are commonly used for thermal regulation in neonates, but their impact on skin integrity is debated.
Purpose of the Study:
- To assess the effect of radiant warmers on the skin barrier function of preterm infants.
- To compare transepidermal water loss (TEWL) and stratum corneum hydration under radiant warmer versus incubator conditions.
Main Methods:
- Transepidermal water loss (TEWL) and stratum corneum hydration were measured in 30 preterm infants across seven body areas.
- Each infant served as their own control, with measurements taken under both radiant warmer and incubator conditions.
Main Results:
- A significant increase in TEWL was observed only on the forehead and upper back under radiant warmer conditions.
- The overall mean difference in TEWL between radiant warmer and incubator conditions was 15%.
- Stratum corneum hydration levels were not significantly affected by the radiant warmer.
Conclusions:
- The use of radiant warmers does not appear to significantly compromise the skin barrier function in preterm infants.
- Findings suggest that radiant warmers can be safely employed for thermal management in preterm neonates without substantial negative effects on skin barrier properties.
Objective:
To evaluate the effect of radiant warmers on skin barrier function in preterm infants.
Methodology:
Transepidermal water loss (TEWL) and stratum corneum hydration were measured in 30 preterm infants (birth weight 825 to 2220 g) in seven body areas: forehead, upper back, cubital fossa, palms, soles, abdomen, and inguinal region. Measurements were performed under radiant warmer and incubator conditions. Each patient served as his/her control.
Results:
TEWL was significantly higher in the radiant warmer compared to the incubator condition in only two areas: forehead and back. The overall mean difference in percentage TEWL between the conditions was 15%. Stratum corneum hydration was not affected by the radiant warmer.
Conclusions:
The use of radiant warmers does not significantly decrease barrier function in the preterm infant.