Detection and quantitation of hepatitis E virus in human faeces by real-time quantitative PCR
Germano Orrù1, Giuseppina Masia, Ginevra Orrù
1Dipartimento di Scienze Odontostomatologiche, Universita' degli Studi di Cagliari, Via Binaghi No. 4, 09121 Cagliari, Italy. orru@unica.it
Abstract:
Hepatitis E Virus (HEV) is the causative agent of an acute and self-limited form of hepatitis. The virus is transmitted by the faecal-oral route and is a major cause of viral hepatitis in much of the developing world where it causes sporadic infections and large-scale epidemics. A simple and rapid protocol for the measurement of HEV faecal shedding by a real-time polymerase chain reaction (PCR) with the SYBR Green method on a LightCycler instrument, is described. After only 3h the real-time quantitative PCR method detected 10 molecules of HEV cDNA fragment per reaction tube and showed a high linear dynamic range of quantitation (10-10(6) molecules of cDNA/reaction) with a good correlation (r = -1.00). Its specificity was confirmed by assay in human faecal samples.