Related Experiment Video
Updated: Aug 10, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Determination of di(2-ethylhexyl)phthalate and mono(2-ethylhexyl)phthalate in human serum using liquid
S Takatori1, Y Kitagawa, M Kitagawa
1Osaka Prefectural Institute of Public Health, 3-69, 1-chome, Nakamichi, Higashinari-ku, Osaka 537-0025, Japan. takatori@iph.pref.osaka.jp
Abstract:
Concentrations of mono(2-ethylhexyl)phthalate (MEHP), and di(2-ethylhexyl)phthalate (DEHP), in serum of healthy volunteers were determined by high performance liquid chromatography (HPLC) with tandem mass spectrometry (LC/MS/MS). The serum was extracted with acetone, followed by hexane extraction under acidic conditions, and then applied to the LC/MS/MS. Recoveries of 20 ng/ml of MEHP and DEHP were 101+/-5.7 (n=6) and 102+/-6.5% (n=6), respectively. The limits of quantification (LOQ) of MEHP and DEHP in the method were 5.0 and 14.0 ng/ml, respectively. The concentration of MEHP in the serum was at or less than the LOQ. The concentration of DEHP in the serum was less than the LOQ. Contaminations of MEHP and DEHP from experimental reagents, apparatus and air during the procedure were less than the LOQ and were estimated to be <1.0 and 2.2+/-0.6 ng/ml, respectively. After subtraction of the contamination, the net concentrations of MEHP and DEHP in the serum were estimated at or <5 and <2 ng/ml, respectively. To decrease contamination by DEHP, the cleanup steps and the apparatus and solvent usage were minimized in the sample preparation procedures. The high selectivity of LC/MS/MS is the key for obtaining reliable experimental data from in the matrix-rich analytical samples and for maintaining a low level contamination of MEHP and DEHP in this experimental system. This method would be a useful tool for the detection of MEHP and DEHP in serum.
More Related Videos
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors