Related Experiment Video
Updated: Aug 4, 2026

Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
In vitro carious lesion detection on D-, E-, and F-speed radiographic films
Ralf Kurt Willy Schulze1, Dirk Nackat, Bernd D'hoedt
1Departmetn of Oral Surgery and Oral Radiology, Dental School, Johannes Gutenberg University of Mainz, Germany. rschulze@mail.uni-mainz.de
Objectives:
To compare the accuracy in detection of interproximal natural carious lesions in vitro between Ultraspeed (D), Ektaspeed Plus (E), and Insight (F) radiographic films.
Study Design:
Ten observers indicated on a 5-point scale their confidence in detecting an interproximal lesion in 240 surfaces (120 extracted teeth) with noncavitated carious lesions. Truth was assessed microscopically from hemisections. The areas (Az) beneath receiver operating characteristic (ROC) curves were pairwise compared and used for a 2-way analysis of variance.
Results:
Az values were significantly correlated with observers (P=.002; Eta=0.671) and film type (P=.003; Eta=0.412). E differed significantly (mean Az: 0.624) from both D (mean Az: 0.591; P=.028) and F (mean Az: 0.594; P=.037), although the 95% confidence intervals clearly overlapped.
Conclusion:
The superior performance of Ektaspeed failed to prove clinical relevance.
More Related Videos
09:34Semi-Automated Planimetric Quantification of Dental Plaque Using an Intraoral Fluorescence Camera
Published on: January 27, 2023
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024