Coherent control of rotational wave-packet dynamics via fractional revivals

Michael Spanner1, E A Shapiro, Misha Ivanov

  • 1NRC Canada, 100 Sussex Drive, Ottawa, Ontario K1A 0R6 Canada.

Related Concept Videos

Effective Value of a Periodic Waveform01:07

Effective Value of a Periodic Waveform

The concept of effective value, the root mean square (RMS) value, is crucial in understanding electrical circuits and power delivery. This idea emerges from the necessity to measure the effectiveness of a voltage or current source in supplying power to a resistive load.
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the system's...
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires careful...
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...