A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Complying with the Occupational Safety and Health Administration's Bloodborne Pathogens Standard: implementing
Michelle A Marini1, Maeve Giangregorio, Joanna C Kraskinski
1*Emergency Services, Children's Hospital, Boston, MA; †Intravenous Therapy Team, Children's Hospital, Boston, MA; ‡Occupational Health Services, Children's Hospital, Boston, MA.
Abstract:
Preventing the transmission of bloodborne pathogens to healthcare workers has been a mission and a challenge of the healthcare industry for over 20 years. The development of the Occupational Safety and Health Administration Bloodborne Pathogens Standard in 1991 and the passing of the Needlestick Safety Act in 2000 mandated hospitals to develop an Exposure Control Plan to protect workers from these pathogens. Children's Hospital Boston began implementation of a needleless system in 1993. Employees readily accepted these systems into practice, because they were convenient and easy to use. A marked decrease in exposures to bloodborne pathogens naturally followed, which is consistent with the national data. The transition to intravenous (i.v.) safety devices at Children's Hospital began in 2000 and proved to be more of a challenge. First, the clinicians must choose a safety product, which requires developing and implementing a trial plan with potential catheters. This selection process is especially difficult in pediatrics where successful placement of the smallest-gauge catheter, no. 24, is imperative. After choosing an i.v. safety product, successful transition is dependent upon the thoroughness of i.v. safety device training and a commitment by the clinicians to the use of these products. Although the number of needlestick injuries and subsequent transmission of bloodborne pathogens have been further reduced with the use of i.v. safety devices, needlestick injuries still occur. This results from a lack of familiarity with the engineering of the device and therefore poor technique or a failure to activate the safety mechanism. Staff resistance due to loss of expertise with the new device and patient care concerns are additional barriers to the use of these new products. Addressing these obstacles and providing adequate training for all clinicians were required for successful implementation of these i.v. safety devices.
Related Concept Videos
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
PPE Use in Healthcare Settings I: Donning