Related Experiment Video
Updated: Aug 8, 2026

Visualization of UV-induced Replication Intermediates in E. coli using Two-dimensional Agarose-gel Analysis
Published on: December 22, 2010
Distribution of single DNA molecule electrophoretic mobilities in semidilute and dilute hydroxyethylcellulose
Yoshinori Yamaguchi1, Todor I Todorov, Michael D Morris
1Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055, USA.
Abstract:
The distribution of center of mass electrophoretic mobility mobilities and normalized migration time of up to 1080 lambda DNA molecules per experiment were measured in both semidilute hydroxyethylcellulose HEC/0.5 x Tris-borate-EDTA (TBE) solutions and dilute HEC/0.5 x TBE solution by high-speed video microscopy. Measurements were made microscopically over a short migration distance in homogeneous DNA HEC/0.5 x TBE solution and after electrophoretic migration of a plug of DNA through 7 cm. Video at 120 frames/s (semidilute HEC solution) and 236 frames/s (dilute HEC solution) allowed visualization with adequate resolution for single molecule mobility measurements. The electrophoretic migration times and band shapes predicted from the measurements corresponded well with those measured by conventional capillary electrophoresis (CE) in both semidilute and dilute HEC. In semidilute solution, the band width predicted by a square root of time scaling is in good agreement with the results of conventional CE. However, in dilute solution the precision of the measurements was not good enough to allow scaled estimates of band widths.
Related Concept Videos
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

