Related Experiment Video
Updated: Aug 24, 2026

Separation of Aldehydes and Reactive Ketones from Mixtures Using a Bisulfite Extraction Protocol
Published on: April 2, 2018
Separation and determination of biphenyl nitrile compounds by microemulsion electrokinetic chromatography with mixed
Suxuan Gong1, Tao Bo, Lan Huang
1Key Laboratory of Bioorganic Chemistry and Molecular Engineering of the Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, PR China.
Abstract:
A mixture of six biphenyl nitrile compounds and three related substances with high hydrophobicity and similar structures was successfully separated by microemulsion electrokinetic chromatography (MEEKC) within 30 min. The microemulsion system contained 100 mM sodium dodecyl sulfate (SDS), 80 mM sodium cholate (SC), 0.81% v/v heptane, 7.5% v/v n-butanol, 10% v/v acetonitrile, and 10 mM borate. The addition of SC, organic modifiers, sample preparation, and temperature all showed remarkable effects on the separation. The capacity factor (k) was calculated by using dodecyl benzene as the marker for microemulsion, and the calculated partition coefficient log P(o/w) of the solutes was in the range of 3.35-7.38. The log k values matched well with the log P(o/w) with a correlation coefficient of 0.96. In addition, the linear correlation coefficients of each compound between peak area and concentration were from 0.996 to 0.998 with the repeatability RSD value < 1.2% for migration time and < 4.8% for peak area, and the highest theoretic plate number was > 586000. MEEKC was compared with micellar electrokinetic chromatography (MEKC) indicating that the former method is more suitable for this separation and can be used for the quality control of biphenyl nitrile compounds in the synthesis of liquid crystals.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Elution Process
Electrophoresis: Overview
There...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...