Related Experiment Video
Updated: Aug 24, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
Published on: February 12, 2014
Phase plate to extend the depth of field of incoherent hybrid imaging systems
Sherif S Sherif1, W Thomas Cathey, Ed R Dowski
1Imaging Systems Laboratory, Campus Box 525, University of Colorado at Boulder, Boulder, Colorado 80309, USA. sherif@colorado.edu
Abstract:
A hybrid imaging system combines a modified optical imaging system and a digital postprocessing step. We describe a spatial-domain method for designing a pupil phase plate to extend the depth of field of an incoherent hybrid imaging system with a rectangular aperture. We use this method to obtain a pupil phase plate to extend the depth of field, which we refer to as a logarithmic phase plate. Introducing a logarithmic phase plate at the exit pupil of a simulated diffraction-limited system and digitally processing the detector's output extend the depth of field by an order of magnitude more than the Hopkins defocus criterion. We also examine the effect of using a charge-coupled device optical detector, instead of an ideal optical detector, on the extension of the depth of field. Finally, we compare the performance of the logarithmic phase plate with that of a cubic phase plate in extending the depth of field of a hybrid imaging system with a rectangular aperture.