Comparison of blood pressure measurement consistency using tonometric and automated oscillometric instruments
Carolyn B Yucha1, Mark C Yang, Pei-Shan Tsai
1College of Nursing, University of Florida, PO Box 100197, Gainesville, FL 32610, USA. yuchacb@nursing.ufl.edu
Abstract:
To effectively evaluate treatments for hypertension, researchers and clinicians must be able to measure blood pressure (BP) in a valid and reliable way. The purpose of this study is to compare measurements made in the clinic using beat-to-beat radial BP tonometry, measurements made during 24 hours using an ambulatory BP monitor, and measurements made in the clinic using an automated oscillometric BP monitor. Fifty-seven adults with primary hypertension participated in this study, which used a repeated measures descriptive design. Clinic and ABPM daytime averages were compatible for both SBP and DBP. In contrast, clinic SBP was 7.56 mmHg higher than the beat-to-beat SBP; clinic DBP was 9.83 mmHg higher than the beat-to-beat DBP. These data suggest that automated clinic measurements may be used in place of daytime ambulatory BP measurements. We also estimate sample sizes for future studies based on characteristics of clinic BP.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement