Related Experiment Video
Updated: Aug 18, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Effect of multislice scanners on patient dose from routine CT examinations in East Anglia
S J Yates1, L C Pike, K E Goldstone
1East Anglian Regional Radiation Protection Service, Addenbrooke's Hospital, Hills Road, Cambridge CB2 2QQ, UK.
Abstract:
As part of the dose optimization process, the Ionising Radiation (Medical Exposure) Regulations 2000 include requirements relating to the assessment of patient dose, and the setting and subsequent review of diagnostic reference levels. In East Anglia, audits of effective dose in CT have been carried out in 1996, 1999 and 2002. In the 2002 audit, nine of the 14 scanners assessed had been replaced since the previous audit. Eight of the new scanners were multislice scanners, acquiring up to 16 slices in a single rotation. The objective of the 2002 audit was to investigate the effect of the introduction of these multislice scanners on patient doses from routine CT examinations. Exposure parameters were collected for 10 different types of routine CT examination. In excess of 550 sets of patient data were obtained. For each of these, effective doses were calculated using the results of Monte Carlo simulations published by the National Radiological Protection Board. Averaged across all 10 examinations, regional mean effective doses are 34% higher than in 1999. The multislice scanners in the region give, on average, 35% more effective dose than the single-slice scanners. The effect of collimation in multislice scanners makes these effective dose differences most notable for examinations that use narrow slice widths. Further optimization of exposures on multislice scanners has the potential to reduce the differences observed between single-slice and multislice doses. However, when taken in combination with the increased use of CT in many hospitals, the effective dose increases observed are likely to result in a significant increase in the already substantial collective radiation dose from CT.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography

