Large-volume injection PTV-GC-MS analysis of polycyclic aromatic hydrocarbons in air and sediment samples
Felice M Norlock1, Jae-Kil Jang, Qimeng Zou
1School of Public Health, University of Illinois at Chicago, USA.
Abstract:
For the analysis of trace organic pollutants in environmental samples using a gas chromatographic (GC) instrument, large-volume injection using the programmable temperature vaporization (PTV) technique has many advantages over the traditional split/splitless injection. By increasing the injection volume from 1 or 2 microL with a split/splitless inlet to 60 microL or higher with the PTV inlet, analytical sensitivity is greatly enhanced for analytes with low concentrations. Results obtained from optimization of instrument operational parameters for analyzing polycyclic aromatic hydrocarbons (PAHs) are reported in this paper. The laboratory method detection limits for 16 PAHs and six deuterated PAH surrogates were determined using seven replicate spike samples. The initial temperature of the inlet was found to be critical in determining the analytical sensitivity of PAHs with two or three rings due to loss of these relatively highly volatile compounds during solvent vaporization. For most PAHs, the response of the mass spectrometry detector increased proportionally as the total injected volume was increased up to 150 microL. Significant interference from rubber material of the sample vial septa was observed.
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...