Related Experiment Video
Updated: Aug 24, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
On-line coupling of high-performance liquid chromatography to a continuous-flow enzyme assay based on electrospray
Arjen R de Boer1, Thomas Letzel, Danny A van Elswijk
1Section Analytical Chemistry & Applied Spectroscopy, Department of Chemistry and Pharmaceutical Sciences, Faculty of Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1083, 1081 HV Amsterdam, The Netherlands,. AR.de.Boer@few.vu.nl
Abstract:
Liquid chromatography (LC) was coupled on-line to a continuous-flow enzymatic assay using electrospray ionization mass spectrometry (ESI-MS) as readout for the screening of enzyme inhibitors in complex samples. Inhibitors were detected by changes in the concentration of the enzymatic reaction products, indicating the inhibition of enzymatic activity. The molecular masses of the inhibitors were determined with high certainty by using retention time matching and peak shape comparison. Due to the high matching accuracy, baseline separation of coeluting analytes was not necessary in order to identify the correct masses of the bioactive compounds. The continuous-flow system was successfully applied for the screening of complex samples, such as natural extracts. For a red clover extract, detection limits of 0.3-0.8 micromol/L were obtained. System validation was performed by determining the IC(50) values of four inhibitors in the flow-injection mode. The IC(50) values were in the 0.11-5.6 micromol/L range and correspond closely to data obtained by microtiter plate assays. Detection limits were in the range of 0.018-0.35 micromol/L in the flow-injection mode, and 0.075-0.75 micromol/L in the LC mode. These values are well below the typical compound concentrations (1-10 micromol/L) used in high-throughput screening. Together with an interday precision of 12.6%, these results demonstrate the applicability of the system for bioactivity screening of complex mixtures, generating both chemical and biological information on bioactive compounds in a single run.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

