Related Experiment Video
Updated: Aug 24, 2026

High-Resolution Respirometry in a Small-Volume Chamber
Published on: July 25, 2025
Comparison of oxygen-transfer measurement methods under process conditions
Stéphanie Capela1, Sylvie Gillot, Alain Héduit
1Water Quality and Hydrology Research Unit of the Cemagref, National Institute of Agricultural and Environmental Engineering Research, Antony, France.
Abstract:
The objective of this paper is to compare the following four methods of measuring oxygen transfer in wastewater treatment plants under process conditions: the offgas, hydrogen peroxide (H2O2), reaeration, and in situ oxygen uptake rate (OUR) methods. Comparative tests were performed under controlled conditions in a pilot column and in six full-scale oxidation ditches equipped with fine-bubble diffusers and slow-speed mixers. The offgas and H2O2 methods give similar results (differences between the oxygen-transfer coefficients under field conditions [k(L)a(f)] from each method lower than 10%). The reaeration procedure gives more random results (differences from -5 to -43% compared with values obtained using the offgas method). The in situ OUR method, in the presence of a horizontal flow of mixed liquor, leads to an estimate of k(L)a(f) to within 15% of the offgas value.