Multiwavelength Implantable Oximeter for Wireless Monitoring of Tissue Oxygenation in the Presence of Blood Volume
Anat Usatinsky1,2, Hugo L Higueros-Garcia1,2, Sadi Loai1,2
1Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.
Abstract:
Real-time continuous measurement of tissue oxygenation (StO2) can provide insight into organ transplant health and disease progression and provide feedback after medical interventions. However, existing optical oximetry approaches typically assume stable blood volume, limiting their usefulness in real-world scenarios involving vasoconstriction, vasodilation, or acute blood loss. Here, we leverage miniaturized optical sensors and Bluetooth microprocessors to create a fully implantable oximeter that measures subdermal tissue oxygenation and accounts for varying levels of blood volume. The device utilizes a wireless radiofrequency (RF) power transfer scheme that allows high bandwidth Bluetooth data transmission from three wavelength channels: green (537 nm), red (660 nm), and near-infrared (NIR) (880 nm). Results show that the addition of a green wavelength improves tissue oxygenation estimation in the presence of varying blood volumes. In silico and in vivo validation of the device and tissue oxygenation algorithm is performed in rats during hypoxia, hypercapnia, and occlusion on a variety of tissues such as paw, subdermal muscle, and kidney. Miniaturized, wireless, battery-free, implantable devices such as these that support mechanisms to compensate for varying blood volumes for StO2 calculations offer the potential for continuous, real-time, physiologically consistent monitoring of blood hemodynamics under dynamic physiological conditions.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...