Post-test calibration of single-use, antimony, 24-hour ambulatory esophageal pH probes is necessary
James L Wise1, Patricia K Kammer, Joseph A Murray
1Department of Gastroenterology and Hepatology, Mayo Clinic, 200 First Street SW, Rochester, Minnesota 55905, USA.
Abstract:
Twenty-four-hour pH monitoring is considered the "gold standard" for detection of gastroesophageal reflux disease (GERD). However, reference pH can drift during studies using antimony pH electrodes. Posttest calibration of antimony probes to assess a "drift" has been advocated but is not routinely preformed in clinical practice. We undertook this study to determine the frequency and degree of drift that occurs during pH studies using single-use antimony pH electrodes. One hundred consecutive 24-hr ambulatory esophageal pH studies were reviewed for presence and degree of pH drift. Separately, 10 in vitro studies using antimony electrodes exposed to solution of constant pH and temperature were recorded to determine timing of drift. Drift of at least 0.1 pH unit occurred in 88 (P < 0.001). Drift of 0.1, 0.2, 0.3, 0.4, and > 0.4 pH unit occurred in 38, 28, 15, 4, and 5 of the 100 studies, respectively. In six studies the adjustment for the poststudy calibration drift changed the overall interpretation of the test. Small degrees of drift occurred at various times during the 10 in vitro studies. Drift in pH during 24-hr pH studies using antimony is common, but large degrees of drift are not. When the threshold of pH 4.0 was adjusted to reflect the drift, a small but significant number of interpretations changed. Drift artifact may impact the results of the pH study, and calibration should be repeated after all studies.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...