Related Experiment Video
Updated: Aug 17, 2026

Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
[Influence of eugenol-containing temporary cement on efficacy of dentin-bonding systems]
Li-Jun Zhang1, Chu-fan Ma, Zhong-yi Wang
1Department of Prosthodontics, College of Stomatology, The Fourth Military Medical University, Xi'an 710032, China.
Objective:
This study investigated the influence of eugenol-containing temporary cement on the efficacy of two relatively new dentin-bonding systems.
Methods:
Thirty-two freshly extracted bovine central incisors were randomly divided into four groups. Dentin was exposed and polished with 320#, 400#, and 600# sand papers. After embedded, Group 3 and 4 specimens were covered with ZOE. Specimens in Group 1 and 2 were served as control. All specimens were stored for 1 week in distilled water at 37 degrees C. Then, the ZOE was mechanically removed. The dentin surfaces of Group 1 and 3 were treated with Prime & Bond NT bonding system and the dentin surfaces of Group 2 and 4 were treated with GLUMA adhesive system according to manufacturer's instructions. Thereafter composite resin columns (6 mm diameter, 2 mm high) were applied. After specimens stored in distilled water at 37 degrees C for 24 hours, the shear bond testing was carried out using a SHIMADZU universal testing machine with a cross-head speed of 0.5 mm/minute. The mode of failure was examined using SEM. The data were analyzed using ANOVA test at a significance level of 0.05.
Results:
The medians of shear bond strength for each group were as follows: Group 1 (Prime & Bond NT) 9.57 MPa, Group 3 (Prime & Bond NT + ZOE) 10.72 MPa, Group 2 (GLUMA) 16.89 MPa, Group 4 (GLUMA + ZOE) 16.78 MPa. Group 1 and 3 had significantly lower bonding strength than did Groups 2 and 4. But no significant difference was found between the control groups and the groups treated with ZOE temporary cement.
Conclusion:
Pretreatment of the dentin with ZOE temporary cement has no adverse influence on the efficacy of two relatively new dentin-bonding systems.
More Related Videos
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Hydration of Cement
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Soundness of Cement