Differentiation of posterior myocardial infarction from right ventricular hypertrophy and normal anterior loop by

Circulation
|December 1, 1978
PubMed

Insights

Echocardiography effectively differentiates posterobasal myocardial infarction (PMI) from right ventricular hypertrophy (RVH) and normal subjects, outperforming electrocardiography (ECG) and vectorcardiography (VCG). This cardiac imaging method offers practical clinical value for diagnosis.

Area of Science:

  • Cardiology
  • Medical Imaging

Background:

  • Differentiating posterobasal myocardial infarction (PMI) from right ventricular hypertrophy (RVH) or normal anterior loop (AL) subjects is challenging using electrocardiography (ECG) or vectorcardiography (VCG).
  • M-mode echocardiography (echo) has shown potential in assessing cardiac chamber size and wall motion abnormalities.

Purpose of the Study:

  • To evaluate the efficacy of echocardiography in distinguishing PMI from RVH and AL, comparing its diagnostic accuracy against ECG and VCG.
  • To determine if echocardiography provides a more direct and accurate method for differentiating these cardiac conditions.

Main Methods:

  • Comparison of ECG, VCG, and M-mode echocardiography (anterior and subxiphoid approaches) in differentiating PMI, RVH, and AL groups.
  • Analysis of cardiac chamber dimensions, wall thickness, and systolic thickening response using echocardiography.
  • Assessment of posterior wall motion specificity using the subxiphoid echocardiographic view.

Main Results:

  • ECG and VCG failed to effectively distinguish between the three cardiac conditions.
  • Echocardiography revealed distinct characteristics: RVH showed increased right ventricular dimensions and wall thickness; AL subjects had normal echo findings; PMI demonstrated reduced posterior left ventricular systolic thickening and ejection indices via the subxiphoid method.
  • The subxiphoid echocardiographic view targets a superior posterobasal left ventricular segment, aiding in PMI differentiation.

Conclusions:

  • Echocardiography, particularly the subxiphoid approach, offers a more direct and clinically significant method for differentiating PMI from RVH and AL compared to ECG or VCG.
  • This imaging technique enhances diagnostic capabilities in complex cardiac cases involving myocardial infarction and hypertrophy.

Related Concept Videos

The Cardiac Cycle01:13

The Cardiac Cycle

The heart beats rhythmically in a sequence called the cardiac cycle—a rapid coordination of contraction (systole) and relaxation (diastole).
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Chambers of the Heart01:16

Chambers of the Heart

The human heart is a complex organ made up of four chambers: the right and left atria and the right and left ventricles. These internal chambers are separated by partitions known as the interatrial and interventricular septa. The exterior of the heart features a groove known as the coronary sulcus that demarcates the atria from the ventricles, while the anterior and posterior interventricular sulci distinguish between the two ventricles.
Deoxygenated blood from the body is received in the right...
Heart Valves01:16

Heart Valves

The human heart is a complex organ with an intricate system of valves that regulate blood flow. There are two main types of valves: atrioventricular (AV) valves and semilunar valves.
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Heart Sounds01:15

Heart Sounds

Heart sounds are generated by the turbulence in blood flow due to the closing of heart valves. These sounds are best perceived slightly away from the valves, where the blood flow disseminates the sound.
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...