Related Experiment Video
Updated: Jul 14, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Determining the relative amounts of positional isomers in complex mixtures of triglycerides using reversed-phase
Michael Malone1, Jason J Evans
1Chemistry Department, University of Massachusetts Boston, Boston, Massachusetts 02125, USA.
Abstract:
A reversed-phase HPLC-tandem mass spectrometry (RP-HPLC-MS-MS) method was refined for the positional analysis of complex mixtures of TAG. This method has the advantages of speed, ease of automation, and specificity over traditional digestion-based methods for the positional analysis of TAG. Collision-induced dissociation (CID) of ammoniated TAG in an ion-trap mass spectrometer produced spectra that were dependent on the FA position. Dominant DAG fragments were formed from the loss of a FA moiety from the ammoniated TAG species. The loss of FA in the outer positions was favored over their loss in the central position. The combination of RP-HPLC and CID produced spectra that were free of the isotope effects that can complicate spectral interpretation in existing methods. The combination also provided selectivity based on the chromatographic fractionation of TAG, in addition to the selectivity inherent in the CID process. Proof-of-concept experiments were performed with binary mixtures of TAG from the SOS/SSO, OSO/OOS, and the PSO/POS/SPO positional isomer systems (where S is 18:0, stearic acid; O is 18:1 (cis-9), oleic acid; and P is 16:0, palmitic acid). Plots of fractional DAG fragment intensities vs. fractional composition of the binary mixtures were linear. These plots were used to determine the fractional composition of each of these isomeric systems in a variety of vegetable oils and animal fats. Current limitations, future developments, and applications of this method are discussed.
Related Concept Videos
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
High-Resolution Mass Spectrometry (HRMS)
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:

