Abstract:
Eight respiratory parameters which might affect the amount of carbon dioxide rebreathing were assessed in seven patients who were breathing spontaneously from large-bore T tube system during the recovery phase from acute respiratory failure. With multivariate regression analysis, the absolute amount of rebreathed CO2 at the connector of endotracheal tube (VINSPCO2) were approximately estimated by using relatively small number of parameters, including minute volume (VEXP), fresh gas inflow to T piece system (VFGI) and preferably by additional parameters concerning CO2 output of the patients.CO2 rebreathing ratio, VINSPCO2 divided by gross outward flux of CO2 at the connector (VEXPCO2), was predicted with simple regression equation by using (VEXP/VFGI) as follows,(VINSPCO2)/(VEXPCO2) = 0.405 + 0.33 x ln (VEXP/VFGI)The maximum (VEXP/VFGI) ratio to prevent rebreathing of CO2 at the connector was 0.30, whereas the ratio to prevent CO2 accumulation due to rebreathing was 0.45.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-III
Acute Respiratory Failure-IV
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...