Related Experiment Video
Updated: Aug 23, 2026

An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Biomechanical study of pedicle screw fixation in severely osteoporotic bone
Stephen D Cook1, Samantha L Salkeld, Tom Stanley
1Tulane University Health Sciences Center, Department of Orthopaedic Surgery, 1430 Tulane Avenue, SL-32, New Orleans, LA 70112, USA. scook2@tulane.edu
Background Context:
Obtaining adequate purchase with standard pedicle screw techniques remains a challenge in poor quality bone. The development of alternate insertion techniques and screw designs was prompted by recognition of potential fixation complications. An expandable pedicle screw design has been shown to significantly improve fixation compared to a conventional screw in poor quality bone.
Purpose:
The purpose of this study was to determine if polymethylmethacrylate (PMMA) bone cement augmentation of an expandable pedicle screw can further improve fixation strength compared to the expandable screw alone in severely osteoporotic bone. A technique for cement insertion into the pedicle by means of the cannulated central portion of the expandable screw is also described.
Study Design:
The axial pullout strength, stiffness and energy absorbed of cemented and noncemented expandable pedicle screws was determined in cadaveric vertebrae.
Methods:
Twenty-one fresh unembalmed vertebrae from the thoracolumbar spine were used. Radiographs and bone mineral density measurements (BMD) were used to characterize bone quality. Paired cemented and noncemented pedicle screw axial pullout strength was determined through mechanical testing. Mechanical pullout strength, stiffness and energy to failure was correlated with BMD.
Results:
Overall, there was a 250% increase in mean pullout strength with the cemented expandable screw compared with a noncemented expandable screw including a greater than twofold increase in pullout strength in the most severely osteoporotic bone. The mean stiffness and energy absorbed to failure was also significantly increased. A cemented conventional screw achieved a pullout strength similar to the noncemented expandable screw.
Conclusions:
PMMA cement augmentation of the expandable pedicle screw may be a viable clinical option for achieving fixation in severely osteoporotic bone.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018