Related Experiment Video
Updated: Aug 23, 2026

Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
Parathyroid reoperation with use of technetium 99m sestamibi radiolocalization and an intraoperative gamma counter
1Department of Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115, USA.
Objective:
To describe a new intraoperative technique for localization of abnormal parathyroid tissue.
Methods:
We report a case and discuss the difficulties encountered in reexploration of the neck area.
Results:
Parathyroid reoperation remains a formidable challenge to even the most experienced endocrine surgeon. Despite the advances in radiographic imaging and localization techniques, accurate intraoperative identification of abnormal parathyroid tissue in a scarred field with obliterated anatomic planes is frequently tedious and occasionally unsuccessful. In a 48-year-old woman with hyperparathyroidism, extensive exploration of the area identified (on the basis of preoperative magnetic resonance imaging and technetium 99m sestamibi scans) as suspicious for the presence of abnormal parathyroid tissue revealed only an aberrant vein. With use of a handheld gamma counter to provide intraoperative guidance during parathyroid reexploration after preoperative intravenous injection of technetium 99m sestamibi, quick identification of a small, intrathyroidal, fifth gland adenoma responsible for persistent primary hyperparathyroidism was facilitated.
Conclusion:
Because of suboptimal precision and specificity, current preoperative localization studies can occasionally provide misleading information. Particularly in difficult cases of parathyroid reexploration, an instrument capable of localizing abnormal parathyroid tissue, which can be used intraoperatively with ease, can be an invaluable tool to ensure a safe, expedient, and successful surgical outcome.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
