Fabrication of alternating polycation and albumin multilayer coating onto stainless steel by electrostatic layer-by-layer adsorption
Related Experiment Video
Updated: Aug 23, 2026

Preparation and High-temperature Anti-adhesion Behavior of a Slippery Surface on Stainless Steel
Published on: March 29, 2018
Jian Ji1, Qinggang Tan, De-Zeng Fan
1Department of Polymer Science, Zhejiang University, Hangzhou 310027, China. jianji@mail.hz.zj.cn
Abstract:
Multilayer films consisting of polyethylenimine (PEI) and albumin were successfully prepared on biomedical 316L stainless steel surface via electrostatic self-assembly of the PEI and albumin. The process of electrostatic self-assembly of PEI/albumin was monitored by125I radiolabeling, electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM). The EIS data revealed that the multilayer coating was stable in Tris-HCl (pH 7.35) buffer solution for 21 days. 125I radiolabeling experiments indicated that less than 10% albumin was eluted by PBS in 45 days. Static platelet adhesion experiments indicated that the PEI/albumin deposited on stainless steel could resist platelet adhesion effectively. Such an easy processing and shape-independent method may have good potential for surface modification of cardiovascular devices.