A clinical evaluation of the 'mini parallel Lack' breathing system in cats and comparison with a modified Ayre's
Catherine M Walsh1, Polly M Taylor
1Department of Clinical Veterinary Medicine, University of Cambridge, Madingley Road, Cambridge CB3 0ES, UK. cmw43@cam.ac.uk
Objective:
To evaluate the suitability of a 'mini parallel Lack' (MPL) breathing system for use in spontaneously breathing cats and to compare the fresh gas flow requirement with that of a modified Ayre's T-piece (MATP).
Animals:
Twenty client-owned cats, ASA I and II, presented for elective procedures requiring anaesthesia.
Materials And Methods:
Pre-anaesthetic medication and induction of anaesthesia were carried out using several techniques commonly used in our teaching hospital. Anaesthesia was maintained with halothane or isoflurane vaporized in either oxygen or with a mixture of oxygen and nitrous oxide. Both breathing systems were evaluated in each cat, with the order of use randomized. Initial fresh gas flows were 300 mL kg(-1) minute(-1) for the MPL and 500 mL kg(- 1) minute(-1) for the MATP. After a 20-minute stabilization period, fresh gas flow was reduced by 200 mL minute(-1) every 5 minutes until re-breathing--defined as an increase in the inspired partial pressure of carbon dioxide to 0.3 kPa (2 mm Hg)--was detected. The fresh gas flow was then increased in 100 mL minute(-1) increments until re-breathing was no longer detectable, and this value was recorded as the minimum fresh gas flow requirement for the breathing system in use. The procedure was then repeated for the second breathing system. Minimum fresh gas flow requirements were compared using a paired Students t-test. Cardiopulmonary variables were compared using anova. Valve opening pressure was measured in the MPL using a manometer.
Results:
The mean (+/-SD) fresh gas flow that prevented re-breathing with the MPL (510 +/- 170 mL minute(-1); equivalent to 142 +/- 47 mL kg(-1) minute(-1)) was significantly lower than that required for the MATP (1430 +/- 560 mL minute(-1); equivalent to 397 +/-155 mL kg(-1) minute(-1)). There were no significant differences in cardiopulmonary variables attributable to the use of the two breathing systems. The MPL valve opening pressure was 1.1 cm H2O.
Conclusions:
The MPL breathing system used lower gas flows than the MATP without affecting cardiovascular or respiratory function. Clinical relevance In spontaneously breathing cats, the MPL offers the advantages of a reduction in cost and atmospheric pollution because less volatile agent is vaporized.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...