Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
A wide range of baroreflex stimulation does not alter forearm blood flow
Reuben Howden1, J Timothy Lightfoot, Michael J Turner
1Physiology of Exercise, De Montfort University, Lansdowne Road, Bedford, UK. howden@niehs.nih.gov
Abstract:
The contribution to the regulation of forearm blood flow (FBF) by different baroreceptor populations has previously only been studied over a limited range of stimuli. Therefore, FBF and R-R interval were recorded during neck suctions and neck pressures ranging from -60 to +40 mmHg. The change in R-R interval (DeltaR-R) during neck suction was significantly increased at each stage when compared to the control ( P<0.05). DeltaR-R did not show any significant change during any of the neck pressure stages ( P>0.05). Suction or pressure applied to the neck did not elicit any significant changes in FBF when compared to the control ( P>0.05). These data show that widening the range of applied stimuli to carotid sinus baroreceptors does not induce a change in FBF. However, the small transient changes reported previously cannot be discounted.
Related Concept Videos
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...