Related Experiment Video
Updated: Aug 23, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Left ventricular diastolic impairment during coronary arteriography with a non-ionic contrast medium
R Baglini1, M Sesana, C Capuano
1Department of Cardiology, Casa di Cura Poliambulanza, Brescia, Italy. robagl@katamail.com
Aim:
The aim of this study was to assess the influence of coronary arteriography with the use of a non-ionic low molecular monomer (iopromide) on left ventricular function.
Methods:
Fifty consecutive patients with coronary artery disease (CAD) and normal left ventricular ejection fraction were studied by coronary arteriography for a stable or unstable coronary syndrome by using iopromide. They were divided into 2 groups: group 1, patients with one vessel disease; group 2, patients with multiple vessel disease. A >50% reduction of the lumen diameter by on-line quantitative angiography was considered a significant coronary stenosis. Coronary arteriography was performed by hand injection of 5 ml of iopromide avoiding the use of nitrates during the procedure. Doppler echocardiography monitoring was performed immediately before the coronary arteriography and at the end of the last coronary injection. The following parameter were recorded: E peak velocity (E) (cm/s), A peak velocity (A) (cm/s), E/A ratio, E deceleration time (EDT) (ms), isovolumic relaxation time (IRT) (ms), and left ventricular ejection fraction (EF) (%).
Results:
No complications were observed during the procedures. A mean amount of 40+/-8 ml of iopromide was used. No significant variation of heart rate and arterial pressure was shown during coronary arteriography. No changes were observed either for E, A, E/A ratio or for left ventricular EF in any group of patients. A significant increase of EDT and IRT in comparison with baseline values was documented only in group 2 (from 140+/-77 to 199+/-44 and from 98+/-33 to 144+/-44, p<0.01), returning to baseline values after 10+/-3 minutes. A positive correlation was observed between EDT and IRT shift from baseline values (r=0.77; p<0.01).
Conclusion:
In conclusion, iopromide temporarily impairs left ventricular diastolic dynamics during selective coronary angiography, but only in patients with multivessel CAD.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...