Related Experiment Video
Updated: Aug 23, 2026

Standardized Protocol to Evaluate the Effect of Surface Treatments, Luting Cements, and Thermocycling on PEEK–Composite Bond Strength
Published on: June 9, 2026
Evaluation of etching time on dentin bond strength using single bottle bonding systems
Amer Abu-Hanna1, Valeria V Gordan
1Department of Operative Dentistry, College of Dentistry, University of Florida, Health Science Center, Gainsville, Florida, 32610-0415, USA. aabuhanna@dental.ufl.edu
Purpose:
Incomplete infiltration of the demineralized collagen network may result in a weak zone within the hybrid layer and between the hybrid layer and dentin. The current study evaluates whether reducing the etching time to 5 s from the recommended 15 s or increasing it to 30 s has an effect on dentin bonding.
Materials And Methods:
108 extracted molars were assigned to 3 bonding agent groups (n = 36): (a) Single Bond (SB), (b) One-Step (OS), and (c) Syntac Single Component (SSC). Each group was further divided into three subgroups (n = 12) of different etching times: 5, 15, and 30 s. All groups were bonded with Z100 composite resin according to the manufacturer's instructions. All specimens were thermocycled 300 times between +/-5 degrees C and +/-55 degrees C, and shear bond strength testing and mode of failure analysis were performed.
Results:
The bond strength of SB (5 s: 15.5 MPa +/- 4.4; 15 s: 16.5 MPa +/- 3.1; 30 s: 16.8 MPa +/- 3.2) and OS (5 s: 13.7 MPa +/- 1.8; 15 s: 12.4 MPa +/- 3.8; 30 s: 10.6 MPa +/- 3.8) showed no significant differences (p < 0.05) for the different etching times. For SSC, different etching times showed significant differences (5 s: 10.9 MPa +/- 1.8; 15 s: 7.5 MPa +/- 2.5; 30 s: 6.4 MPa +/- 2.1). The mode of failure for SB and OS was adhesive or mixed adhesive/cohesive. For SSC, all failures were adhesive.
Conclusion:
Etching times of less than 15 s do not seem to adversely affect bonding to dentin.
Related Concept Videos
Testing Water Quality
Bonding and Strength of Aggregate
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...