Evaluation of unscanned-mode soft-tissue thermal index for rectangular sources and proposed new indices
William D O'Brien1, Yan Yang, Douglas G Simpson
1Bioacoustics Research Laboratory, Department of Electrical and Computer Engineering, University of Illinois, Urbana, IL 61801, USA. wdo@uiuc.edu
Abstract:
The monopole-source solution was used to calculate the three-dimensional complex acoustic pressure field for one-dimensional focused rectangular apertures in a medium having homogeneous acoustic and thermal properties. For each of six frequencies (1, 3, 5, 7, 9 and 12 MHz) and three focuses (f/1, f/2 and f/4), 33 rectangular aperture cases were investigated, for a total of 594 cases. For these focused field geometries, the three-dimensional temperature distribution was calculated using the bioheat transfer equation in homogeneous perfused media (attenuation = absorption: 0.3 dB/cm-MHz; perfusion length: 1.0 cm). For each of the 594 cases, the acoustic field was normalized to the derated spatial-peak temporal-average intensity (ISPTA.3) of 720 mW/cm2, the maximum value condition allowed based on the U.S. Food and Drug Administration (FDA) regulatory limit for most diagnostic ultrasound (US) equipment. Using the normalized acoustic field, the axial temperature increase profiles and the maximum temperature increases (DeltaTmax) were determined for each case. Also, from the normalized acoustic field, the unscanned-mode soft-tissue thermal index (TIS) for the rectangular sources was determined according to the procedures of the Standard for Real-Time Display of Thermal and Mechanical Indices on Diagnostic Ultrasound Equipment, commonly called the output display standard, ODS. The DeltaTmax:TIS ratio of the 594 cases yielded a mean value of 0.22, a median value of 0.16, a maximum value of 1.04 and a minimum value of 0.039. For all but one of the cases, TIS was greater than DeltaTmax. Also, two new unscanned-mode soft-tissue thermal indices (denoted TIS(new1) and TIS(new2)) were proposed. For new model 1, the DeltaTmax: TIS(new1) ratio yielded a mean value of 1.02, a median value of 1.01, a maximum value of 1.83 and a minimum value of 0.44. For new model 2, the DeltaTmax: TIS(new2) ratio yielded a mean value of 1.04, a median value of 0.99, a maximum value of 2.31 and a minimum value of 0.34. Further, both new models fit more closely to DeltaTmax than does the ODS-determined TIS and have the potential of being easier for manufacturers to implement because only the source power and frequency need to be measured.
More Related Videos
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
10:23A Computational Modeling Approach to Investigate the Influence of Hyperthermia on the Tumor Microenvironment
Published on: December 1, 2023
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...