Related Experiment Videos
Anterior cruciate reconstruction using a Dacron ligament prosthesis. A long-term study
J C Richmond1, C J Manseau, R Patz
1Department of Orthopaedic Surgery, New England Medical Center Hospital, Boston, Massachusetts.
The American Journal of Sports Medicine
|January 1, 1992
Summary
Dacron ligament prosthesis for anterior cruciate ligament (ACL) reconstruction showed a high failure rate of 37.1% in a 50-month follow-up. Performance improved initially but deteriorated over time, especially in complex cases.
Area of Science:
- Orthopedic Surgery
- Sports Medicine
- Biomaterials Science
Background:
- Chronic anterior cruciate ligament (ACL) insufficiency often requires surgical reconstruction.
- Prosthetic graft materials are explored as alternatives to autografts or allografts.
- Long-term outcomes of synthetic ligament prostheses require thorough investigation.
Purpose of the Study:
- To evaluate the efficacy and long-term outcomes of Dacron ligament prosthesis for ACL reconstruction.
- To determine the failure rate and identify factors associated with poor outcomes.
- To assess changes in patient performance and laxity over time.
Main Methods:
- A prospective, single-center study involving 35 patients with chronic ACL insufficiency.
- All patients underwent ACL reconstruction using a Dacron ligament prosthesis by a single surgeon.
- Follow-up averaged 50 months, with failure defined by clinical laxity, instrumented laxity, or arthroscopic findings.
Main Results:
- An overall failure rate of 37.1% (13/35 patients) was observed.
- The failure rate was higher in the 'salvage' group (78%) compared to isolated ACL insufficiency (23%).
- Initial improvements in laxity, Lysholm, and Tegner scores were noted at 2 years, followed by performance deterioration.
Conclusions:
- Dacron ligament prosthesis for ACL reconstruction is associated with a high failure rate.
- Outcomes appear worse in patients requiring revision or with multiple instabilities.
- The long-term durability and functional performance of this synthetic graft are questionable, showing late deterioration.