Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Assessment by monte carlo simulation of thermodynamic correlation of retention times in dual-column temperature
1Department of Chemistry and Biochemistry, Southern Illinois University at Carbondale, Carbondale, IL 62901-4409, USA. davis@chem.siu.edu
Abstract:
The correlation of retention times in comprehensive two-dimensional gas chromatography caused by correlation of enthalpy and entropy changes between two stationary phases, methylsilicone and poly(ethylene glycol), was examined using commercial GC software and in-house Monte Carlo simulation. The enthalpy change, deltaH0, and entropy change, deltaS0, of 93 compounds were predicted from isothermal one-dimensional gas chromatograms predicted by the software. These values then were mimicked by Monte Carlo simulation, which removed the strong correlation of deltaH0 and modest correlation of deltaS0 between the two phases. Retention times in a comprehensive two-dimensional gas chromatogram (GC x GC) and in simulations of it were predicted for typical dual-capillary temperature-programmed conditions using the actual, correlated values of deltaH0 and deltaS0 and their uncorrelated Monte Carlo counterparts, respectively. The uncorrelated deltaH0 and deltaS0 values caused the retention-time range of the simulations' second dimension to expand substantially beyond that in the GC x GC. Other simulations were developed using a restricted range of uncorrelated deltaH0 and deltaS0 values to mimic more closely the retention-time range of the GC x GC's second dimension. The intervals between nearest neighbor retention-time coordinates were calculated in both the latter simulations and the GC x GC. The intervals were larger in the simulations than in the GC x GC because the former contained uncorrelated coordinates and the latter contained correlated ones, which clustered along or near the diagonal. The retention times in the first dimension of the GC x GC were Poisson distributed, as assessed by statistical-overlap theory. In contrast, the two-dimensional reduced retention-time coordinates in the GC x GC were not Poisson distributed, because retention times were correlated. However, the reduced retention-time coordinates in the simulations were Poisson distributed.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Chromatographic Methods: Terminology
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...