The ICH guidance in practice: stress degradation studies on indinavir sulphate and development of a validated
Neeraj Kaul1, Himani Agrawal, A R Paradkar
1Department of Quality Assurance Techniques, Bharati Vidyapeeth Deemed University, Poona College of Pharmacy, Erandwane, Pune 411038, Maharashtra, India.
Abstract:
A sensitive, selective, precise and stability-indicating high-performance thin layer chromatography (HPTLC) method for analysis of indinavir sulphate both as a bulk drug and in formulations was developed and validated. The method employed TLC aluminium plates precoated with silica gel 60F-254 as the stationary phase. The solvent system consisted of carbon tetrachloride/chloroform/methanol/10% v/v ammonia (4:4.5:1.5:0.05, v/v/v/v). Densitometric analysis of indinavir sulphate was carried out in the absorbance mode at 260 nm. This system was found to give compact spots for indinavir sulphate (Rf value of 0.43 +/- 0.02, for six replicates). Indinavir sulphate was subjected to acid and alkali hydrolysis, oxidation, dry and wet heat treatment, and photo degradation. The drug undergoes degradation under acidic and basic conditions, oxidation, dry and wet heat treatment, and photo degradation. Also the degraded products were well resolved from the pure drug with significantly different Rf values. The method was validated for linearity, precision, robustness, limit of detection (LOD), limit of quantitation (LOQ), specificity and accuracy. Linearity was found to be in the range of 100-6000 ng/spot with significantly high value of correlation coefficient r2 = 0.997 +/- 0.64. The linear regression analysis data for the calibration plots showed good linear relationship with r2 = 0.999 +/- 0.002 in the working concentration range of 1000-6000 ng/spot. The LOD and LOQ were 40 and 120 ng/spot, respectively. Statistical analysis proves that the method is repeatable and specific for the estimation of the said drug. As the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. Moreover, the proposed HPTLC method was utilized to investigate the kinetics of acid degradation process. Arrhenius plot was constructed and activation energy was calculated.
Related Concept Videos
In Vitro Drug Dissolution: Alternative Methods
Clinically Relevant Drug Product Specifications: Methods of Establishment