Precision and detection limit of quality test for amorphous drug in powder X-ray diffractometry

Shinichi Kitahara1, Tsuneo Ishizuka, Toshihiro Kikkoji

  • 1Chemistry Lab., Pharmaceutical Development Department, Meiji Seika Kaisha, LTD., 760 Morooka-cho, Kohoku-ku, Yokomama 222-8657, Japan. Shinichi_Kitahara@meiji.co.jp

Related Concept Videos

X-ray Diffraction of Biological Samples01:10

X-ray Diffraction of Biological Samples

X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are  scattered by the electron clouds around the sample atoms. The  X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Determination of Crystal Structures01:29

Determination of Crystal Structures

In the late 1800s, the revelation that light extended beyond visible wavelengths led to the discovery of X-rays by Wilhelm Roentgen. Recognized as high-energy electromagnetic radiation with short wavelengths, X-rays prompted exploration into their interaction with crystals. Max von Laue proposed in 1912 that the periodic arrangement of atoms, ions, or molecules in crystals would cause them to diffract X-rays, a hypothesis confirmed through experiments with copper sulfate and zinc sulfide...
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
X-ray Crystallography02:18

X-ray Crystallography

The size of the unit cell and the arrangement of atoms in a crystal may be determined from measurements of the diffraction of X-rays by the crystal, termed X-ray crystallography.
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...