Uncertainty evaluation of radon measurements with LR115 detector and spark counter

F Campi1, M Caresana, M Ferrarini

  • 1Dipartimento di Ingegneria Nucleare, Politecnico di Milano, via Ponzio 34/3, 20133 Milan, Italy.

Related Concept Videos

Uncertainty: Overview00:59

Uncertainty: Overview

In analytical chemistry, we often perform repetitive measurements to detect and minimize inaccuracies caused by both determinate and indeterminate errors. Despite the cares we take, the presence of random errors means that repeated measurements almost never have exactly the same magnitude. The collective difference between these measurements - observed values - and the estimated or expected value is called uncertainty. Uncertainty is conventionally written after the estimated or expected value.
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Contaminants and Errors01:16

Contaminants and Errors

Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
Another key consideration is determining the appropriate number of samples required to...