Hinfinity fuzzy control design for nonlinear singularly perturbed systems with pole placement constraints: an LMI

Wudhichai Assawinchaichote1, Sing Kiong Nguang

  • 1Department of Electrical and Electronics Engineering, The University of Auckland, Auckland, New Zealand. wass001@ec.auckland.ac.nz

Related Concept Videos

Pole and System Stability01:24

Pole and System Stability

The transfer function is a fundamental concept representing the ratio of two polynomials. The numerator and denominator encapsulate the system's dynamics. The zeros and poles of this transfer function are critical in determining the system's behavior and stability.
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's response.
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires careful...
Control System Problem01:21

Control System Problem

In an open-loop system, such as a basic thermostat, the poles of the transfer function influence the system's response but do not determine its stability. However, when feedback is introduced to form a closed-loop system, such as an advanced thermostat that adjusts heating based on room temperature, stability is governed by the new poles of the closed-loop transfer function.
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Construction of Root Locus01:15

Construction of Root Locus

The construction of a root locus involves several key steps to analyze and visualize the behavior of a system's poles with varying gain. The number of branches in the root locus equals the number of closed-loop poles and is symmetrical about the real axis.
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain increases.
Properties of the Root Locus01:05

Properties of the Root Locus

The root locus method is an invaluable tool for analyzing higher-order systems without needing to factor the denominator of the transfer function. A pole of the system is identified when the characteristic polynomial in the transfer function's denominator equals zero.
To determine if a point lies on the root locus, the criterion involves the sum of angles contributed by all poles and zeros to that point. Specifically, this sum must be an odd multiple of 180 degrees. The gain at any point on the...
Plotting and Calibrating the Root Locus01:19

Plotting and Calibrating the Root Locus

Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is observed...