Background:
Pulmonary vein potentials recorded at the ostia of pulmonary veins (PV) are a useful guide for segmental isolation of the PV in patients with atrial fibrillation (AF). Even during coronary sinus pacing at 600 ms, atrial (A) and PV potentials can overlap in 50-60% of patients making the accurate identification of PV potentials very difficult.
Methods:
Nineteen patients (M:F 15:4) with paroxysmal AF underwent segmental isolation of one or more PV. Coronary sinus (CS) pacing was performed at cycle lengths of 600/550/500/450/400/350/300 ms and bipolar electrograms were recorded from the 10 or 20 pole Lasso catheter placed at the atrial-PV junction in 27 pulmonary veins. Stimulus (S) to A, S-PVP and A-PVP intervals were measured during CS pacing at the different cycle lengths at sweep speed of 200 mm/sec.
Results:
During CS pacing at 600 ms the A and PV potentials were significantly overlapped (A-PVP < or = 25 ms) in 15 of 27 (55%) veins. During pacing at 300 ms, the A and PV potentials were significantly separated (A-PVP > or = 25 ms) in 9 of the 15 veins where A and PV potentials overlapped and 21 of all 27 (78%) veins. In two patients pacing at 300 ms was associated with 2:1 conduction block from atrial to PV fascicle.
Conclusions:
Coronary sinus pacing at cycle length of 300 ms demonstrated better separation of A and PV potentials compared to pacing at 600 ms. This strategy is easier and less time consuming compared to extrastimuli testing. It also confirms that the electrophysiological properties of PV fascicles are different from that of the adjacent atrial musculature.
Related Concept Videos
Dysrhythmias III: Characteristics of Dysrhythmias
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...